page up 

Railway Industry

CompetenceKey Facts

EMC and Radio testing, on-site testing, shielding effectiveness testing, consulting, training, troubleshooting, EMF exposure testing, Vehicle Directive testing, aircraft susceptibility tests against Transmitting Portable Electronic Device (T-PED) signals acc. ED-130, tests to manufacturer EMC specifications, calibrations

Consumer Electronics, EMC and Radio
DAkkS Accredited EMC LaboratoriesAccredited EMC tests acc. to nearly all essential commercial EMC standards (European, US, Canadian, Australian, New Zealand)
ISO, IEC, EN, FCC, VDE, CISPR, ICES, AS/NZS, CSA
DAkkS Accredited Radio LaboratoriesAccredited Radio tests acc. to European, US, Canadian, Australian, New Zealand radio standards
ETSI EN, FCC, ANSI/TIA, ANSI/IEEE, RSS, BETS, AS7NSZ,
FCC listed test facilitiesRadiated and conducted emissions tests for Certifications under Part 15 and 18 of the FCC Rules
FCC Listing # 878769
Industry Canada registred test facilitiesRadiated emission testing on radio equipment for Industry Canada
Certification
Industry Canada Registration # 3464C-1
VCCI registered test facilitiesTesting of IT equipment to VCCI rules (based on CISPR standards); VCCI = Voluntary Control Council for Interference by Information Technology Equipment
Radiated Immunity acc. EN/IEC 61000-4-3 from 20 MHz to 3 GHz, up to 10 (20) V/m; Radiated Emissions of Radio Equipment, Precompliance Measurement CE;
CISPR25 Emissions Measurement
Fully Anechoic Room; 9980 mm x 5030 mm x 4950 mm; Door 1538mm x
2185mm BxH; Measurement dist.: 3 m; Turnt:. d = 2 m, 1 t/m2; Absorbers:
249 m² ferrites, 59 m² 50 cm pyramids; Performance: 30 MHz to 18 GHz
acc. to CISPR 16-1-4, 80 MHz to 18 GHz acc. to IEC 61000-4-3; Supply
voltages 250/440VAC/32A/50/60Hz and 115/200V/32A/400Hz;
compressed air; feedthrough plates for EUT monitoring & control
Radiated Emissions measurements acc. to european and international Standards, fulfils NSA requirements acc. to CISPR 16-1-4 chapter 5.7 within the frequency range 30 MHz to 1 GHz for test distances of 3 m and 10 m within a test volume of up to 4 m diameter; with additional floor absorbers free space emission tests up to 18 GHz, test site fulfils requirements acc. to CISPR 16-1-4 chapter 8 for emissions measurements in 3 m distance within the fequency range 1 GHz to 6 GHz in test volume of 4 m diameter and 2.3 m height; Radiated Immunity testingFCC-Listing # 878769; Industry Canada Registration # 3464C-1; VCCI
Registration #R-2958; 21400 mm x 14000 mm x 7800 mm (LxWxH),
sliding door 2588mm x 2568mm BxH (effective 2.5mx 2.5m due to access
tunnel!); Turntable 4m/5t, Speed 0.4° ... 12° per sec, Accuracy 0.5°;
Supply voltages 250/440VAC/63A/50/60Hz and 115/200V/32A/400Hz,
compressed air, water, exhauster for combustion engines (1000m3/h),
feedthrough plates for EUT monitoring & control; build year: 2006
acc. to EN/IEC 61000-4-3 in the frequency range 80 MHz to 6 GHz, up to 10 (20) V/m on systems with up to 4 m diameter
Shielding attenuation tests: clear opening for test material 1900mm x 1200mm, 900mm x 900mm or smaller, Conducted Emissions tests, Conducted Immunity testsFCC and VCCI Listing for Conducted Emissions tests; 8.5mx5.1m, Door
1.2m x 2,1 m; Supply voltages 250/440VAC/32A/50/60Hz and
115/200V/32A/400Hz; compressed air; feedthrough plates for EUT
monitoring & control
Radio tests acc. to european ETSI standards and international (FCC, Industry Canada, Japanese etc.) specifications; with external mixers up to 325 GHz20 Hz to 50 GHz; -150 dBm to 30 dBm; RBW 1 Hz to 50 MHz
Emissions measurements acc. to european and international Standards (EN, ETSI, FCC, IEC …), conforming to standards Emissions measurements (CISPRAV), Fieldstrength measurements up to 8 GHz, fast measurements with FFT available20 Hz to 8 GHz; -155 dBm to 30 dBm; RBW 1 Hz to 10 MHz
OATS and Underground LaboratoryEmissions measurements and Immunity tests on large equipment &
systems; test site not yet complete (groundplane missing!); test site not
listed; planned as real OATS with test distances up to 30 m as well as
Antenna test site (Calibration Site)
21m x 41m; Underground laboratorium with shielded test room for test personell and equipment, feedthroughs for antenna cable prepared in various test distances; turntable 4m/5t (same as SAC)
ESD tests, conducted immunity tests, conducted emissions tests5.3x3.5x3m, Door 0.95m; Supply voltages 250/440VAC/32A/50Hz;
compressed air; feedthrough plates for EUT monitoring & control
Field Probe Calibration, Radiated Immunity tests, Radiated emissions tests (precompliance) (GTEM Cell)6,35m x 3,58m x 2,55m (LxWxH), door: 1m x 1,3m, 50ohm, 0,01...18GHz,
test volume: 0,85 x 0,85 x 0,45 (m)³, max 1000W, filter 230 VAC/16A, 400
VAC 4 x 25A
Emissions measurements up to 26.5 GHz; with external mixers up to 325 GHz, Attenuation measurements (tracking generator up to 26.5GHz)20Hz...26.5GHz, TG 100Hz...5GHz
-38...137 dBμV
20Hz...26.5GHz, TG 100Hz...5GHz
-38...137 dBμV
TG FOR ESMI 5...26GHz
-75...0dBm
Shielding attenuation tests 30 MHz to 1,5 GHz on material samples with approx.
150 mm diameter
ASTM D4935, 30 MHz…1.5 GHz, 2x Nm, 2x10 dB Attn (9210-02/-03,
DC…8GHz) test specimes gold film, dynamic range specimes alu, 12 kg
Vektor Netzwork Analysis 9 kHz to 6 GHz; Calibration of test equipment;
Emissions measurement (pre-compliance), fault detection & localisation (TDR) (e.g. cable)
9kHz…6GHz, Opt: spectrum analysis, Calibration Kit N (1-18 GHz)
Demodulation AM/FM/PM, OCXO, GPIB, preamplifier 20dB, DC 12-28V,
AC 100-240V, 50-400 Hz, 7 kg, Option ZVL-K2 DTF

Current Seminars

2018-11-14 to 2018-11-16

  • EMC-Basics, Test and Measurement-Seminar for MIL and Avionic Standards

2018-11-15 to 2018-11-16

  • Test and Measurement-Seminar for MIL and Avionic Standards

2018-11-19 to 2018-11-21

  • EMC-Basics, HIRF/HERF – Electromagnetic Effects in Aircraft

2018-11-20 to 2018-11-21

  • HIRF/HERF – Electromagnetic Effects in Aircraft

2018-11-22 to 2018-11-23

  • Lightning Electromagnetic Effects on Aircraft

More information

page down 
© 2018 EMCC DR. RAŠEK. All Rights Reserved.