Ford Anerkennung

Die Laboratorien von EMCCons DR. RAŠEK sind von der Ford Motor Company für die Durchführung von EMV-Tests nach den folgenden Spezifikationen und Verfahren anerkannt:

FORD EMC Specification: EX-XW7T-1A278-AC: Component and Subsystem Electromagnetic Compatibility. Worldwide Requirements and Test Procedures
EMC Test Procedures covered by FORD Recognition

Test Titel Base Specification
RI 112 RF Immunity: RI 112 – BCI Method ISO 11452-4
RI 114 MTR all bands RF Immunity: RI 114 – Reverberation Method IEC 61000-4-21
RI 114 ALSE Bands 4 & 5 RF Immunity: RI 114 – ALSE Method ISO 11452-2
RI 114 ALSE Bands 6 & 7 RF Immunity: RI 114 – ALSE Method ISO 11452-2
RI 130 Coupled Immunity: RI 130 – Immunity from Inductive Transients -
RI 150 Coupled Immunity: RI 150 – Charging System Noise -
RI 140 Magnetic Field Immunity: RI 140 MIL-STD-461E
CI 210 Immunity from Continuous Disturbances: CI 210 -
CI 220 Immunity from Transient Disturbances: CI 220 ISO 7637-2
CI 230 Immunity to Power Cycling: CI 230 -
CI 250 Immunity to Voltage Offset: CI 250 -
CI 260 Immunity to Voltage Dropout: CI 260 -
CI 270 Immunity to Voltage Overstress: CI 270 -
CI 280 Electrostatic Discharge: CI 280 ISO 10605: 2001
RE 310 Radiated RF Emissions: RE 310 IEC CISPR 25
CE 410 Conducted Transient Emissions: CE 410 ISO 7637-2
CE 420 Conducted RF Emissions: CE420 IEC CISPR 25

FORD EMC Specification:  FMC1278: Electromagnetic Compatibility Specification for Electrical / Electronic Components and Subsystems
EMC Test Procedures covered by FORD Recognition

Test Titel Base Specification
RI 112 RF Immunity: RI 112 – BCI Method ISO 11452-4
RI 114 ALSE Bands 5 & 6 RF Immunity: RI 114 – ALSE Method ISO 11452-2
RI 114 ALSE Bands 7 & 8 RF Immunity: RI 114 – ALSE Method ISO 11452-2
RI 115 RF Immunity to hand portable transmitters: RI 115 ISO 11452-9
RI 130 Coupled Immunity: RI 130 – Immunity from Inductive Transients -
RI 150 Coupled Immunity: RI 150 - Charging and ignition system disturbances -
RI 140 Magnetic Field Immunity: RI 140 MIL-STD-461E
CI 210 Immunity from Continuous Power Line Disturbances: CI 210 -
CI 220 Immunity from Transient Disturbances: CI 220 ISO 7637-2
CI 221 Immunity from Transient Disturbances: CI 221 ISO 7637-2
CI 222 Immunity from Load Dump: CI 222 ISO 7637-2: 2004
CI 230 Immunity to Power Cycling: CI 230 -
CI 231 Immunity to Power Cycling: CI 230 ISO 7637-2
CI 250 Immunity to Voltage Offset: CI 250 -
CI 260 Immunity to Voltage Dropout: CI 260 -
CI 270 Immunity to Voltage Overstress: CI 270 -
CI 280 Electrostatic Discharge: CI 280 ISO 10605: 2008
RE 310 Radiated RF Emissions: RE 310 CISPR 25: 2008
CE 420 Conducted RF Emissions: CE420 CISPR 25: 2008
CE 421 Conducted Emissions: CE421 -

FORD EMC Specification: EMC-CS-2009.1: Electromagnetic Compatibility Specification For Electrical / Electronic Components and Subsystems
EMC Test Procedures covered by FORD Recognition

Test Titel Base Specification
RI 112 RF Immunity: RI 112 – BCI Method ISO 11452-4
RI 114 ALSE Bands 4 & 5 RF Immunity: RI 114 – ALSE Method ISO 11452-2
RI 114 ALSE Bands 6 & 7 RF Immunity: RI 114 – ALSE Method ISO 11452-2
RI 115 RF Immunity to hand portable transmitters: RI 115 ISO 11452-9
RI 130 Coupled Immunity: RI 130 - Immunity from Inductive Transients -
RI 150 Coupled Immunity: RI 150 - Charging System Noise -
RI 140 Magnetic Field Immunity: RI 140 MIL-STD-461E
CI 210 Immunity from Continuous Disturbances: CI 210 -
CI 220 Immunity from Transient Disturbances: CI 220 ISO 7637-2
CI 230 Immunity to Power Cycling: CI 230 -
CI 250 Immunity to Voltage Offset: CI 250 -
CI 260 Immunity to Voltage Dropout: CI 260 -
CI 270 Immunity to Voltage Overstress: CI 270 -
CI 280 Electrostatic Discharge: CI 280 ISO 10605: 2001
RE 310 Radiated RF Emissions: RE 310 IEC CISPR 25
CE 410 Conducted Transient Emissions: CE 410 ISO 7637-2
CE 420 Conducted RF Emissions: CE420 IEC CISPR 25
CE 421 Conducted AF Emissions: CE421 IEC CISPR 25